Fuel Oil Pump Sets

Pump Sets

Duplex Pump Sets are designed to reliably provide fuel oil to emergency generators or boilers. The pump sets are complete packages with all the pumping equipment mounted to a skid with all the controls either mounted to the pump set skid or mounted remotely. All control panels are UL508 designed.

Pump sets are available to meet the demands of your application and facility. Pump sets can range from very simple systems typically found on boiler loop applications to multi-generator systems involving backup features. Custom designed pump skids for heavier oils or other application requirements are available.

If you need to check stock, get a quote or just have a question
please call us at 630-627-4737
or send an email to jhauge@becequipment.com and we will be happy to assist you.

Features
• Skid or Enclosure Designs
• Color Touch Screen
• Pump Rates from 90 to 1000+ GPH Available
• Design Pressures of 50, 100, and Up
• Simplex or Duplex Strainer
• Standard Built and Custom Configurations
• Building Automation System (BAS) Interfaces

Applications
• Diesel Supply to Emergency Generators
• Oil Supply to Boilers for Primary or Backup Fuel Supply

Product Features

The Automatic Fuel Oil Transfer Pump Set (ATPSF) is a state-of-the-art duplex pump sequencing and monitoring system factory packaged, pre-engineered, pre-wired and pre-plumbed system that includes pumps, industrial motors, and accessories. This system includes automatic lag pump back-up features that improve fuel system availability and safety. The ATPSF pump set has been upgraded to include the Preferred Flexible System Controller (FSC) to reduce field wiring and commissioning time.

Standard Equipment Includes:

  • Microprocessor-based control with color touchscreen display and alarm/event and operator action log in a NEMA 4 enclosure.
  • Included FSC controller communicates by redundant digital link to other FSC controllers on day tanks, filtration sets, and fill boxes to reduce field wiring.
  • Control circuit transformer (if required)
  • Alarm bell with alarm silence/reset pushbutton
  • Two “Hand-Off-Auto” switches
  • “Pump On” indicators
  • Two magnetic motor starters with overload protection
  • Two motor circuit breakers
  • Two pump and motor assemblies
  • Two Simplex Inlet Strainers
  • Two relief valves, two check valves and four ball valves
  • Pump Discharge Pressure Gauges
  • Pump set flow proving switch (shipped loose)

Duplex Strainer (Option “-D”): A Preferred Model 72 duplex fuel oil strainer is provided on the suction side of the pump set instead of the two simplex strainers.  Strainer baskets are 40 mesh stainless steel.

Duplex Strainer Differential Pressure Switch (Option “-DP”): A differential pressure switch/ indicator with isolation cocks is provided to energize an audible and visual alarm should an excessively dirty strainer condition be detected (Option “-DP”  can only be used with option “-D”).

Automatic Pump Prime And Suction Line Integrity Check: Fuel transfer system suction piping, pump prime and pump operation are automatically verified each week (adjustable). The lead pump is automatically energized. Once the lead pump has been proven, the lag pump is energized and run through the same test. These tests are recorded in the controller memory with a time-date stamp for later verification. If either lead or lag pump fails any of these tests, the control system generates an audible and visual alarm and logs the “failed pump” condition.  To permit pump set testing, fuel oil piping system design must allow the pump set discharge to return to the main storage tank.  The above diagrams show suitable Boiler Loop and Day Tank system arrangements. Additionally, system designs may include return flow pumps or solenoid valves. Consult factory for additional information.

Main Storage Tank Monitoring (Optional): Fuel Sentry Model TG-EL-D4A tank gauges may be integrated into the Model ATPSF Transfer Pump Set.

Modbus Communication Interface: Off-site monitoring and control is available via RS-485 Modbus, Ethernet TCP/IP, or BacNet IP digital communication.

Alarms / Event Summary: Up to 200 alarms, system events and operator actions are listed in “first in-first out” order with time & date stamp. Alarms include “pump thermal overload,” “pump loss of flow,” and “pump set failure” with “day tank leak,” “day tank high level” and “day tank low level” alarms added for day tank systems. The following events are recorded with time & date stamp: “pump started,” “pump control switch in ‘off’ position,” “pump set prime test OK” and “pump selected as lead.”

Pump Set Leak Detector Switch (Option “-L”): A float-operated “containment basin leak” detection switch is provided to shut off the pumps and energize an audible and visual alarm should a pump set leak be detected.

Automatic Fuel Oil Transfer Pump Set
Duplex Pump Sets are designed to reliably provide fuel oil to emergency generators or boilers. The pump sets are complete packages with all the pumping equipment mounted to a skid with all the controls either mounted to the pump set skid or mounted remotely. All control panels are UL508 designed.
Download the Automatic Fuel Oil Transfer Pump Set Cutsheet: HERE

Fuel Oil Day Tanks
he Model DT Day Tanks provide a local supply of distillate or diesel fuel for boilers, emergency generators or other stationary engine driven or oil fired equipment.  Available from 20 to 620 gallon capacities, a properly sized tank may be selected per individual job.  For maximum fuel capacity in a minimum space, Preferred Day Tanks are rectangular in shape. Each Day Tank unit includes all necessary pipe connections, inspection port, manual fill port, and tank gauge, along with a variety of optional accessories.
Download the Fuel Oil Day Tanks Cutsheet: HERE

Automatic Fuel Oil Filtration Sets
Our Automatic Fuel Oil Filtration Sets are the most complete, efficient and reliable engine protection systems you can install.  These self-contained, fully automatic systems remove water, suspended rust, dirt and other contaminants in order to maintain the quality and purity of stored diesel fuel.
Download the Automatic Fuel Oil Filtration Sets Cutsheet:  HERE

If you need to check stock, get a quote or just have a question
please call us at 630-627-4737
or send an email to jhauge@becequipment.com and we will be happy to assist you.